Reviewing Attic Ventilation During a Reroof
Use the reroof to confirm the existing ventilation design and which openings change. A standard shingle price may leave attic work outside the bid.

What matters most
- Ridge length — 40 ft (example roof plan length).
- Soffit edges — 70 ft (example potential intake edges).
- Net free area — Product-specific (obtain ratings and usable lengths).
Identify the attic and roof assembly
Ask the contractor to identify whether the attic is vented or uses a different enclosure strategy. Record existing intake, exhaust, blocked paths and where ducts terminate. Confirm who evaluates any condensation, indoor air leakage or ventilation problem separately from replacement of the roof covering.
Compare existing and proposed openings
In a simple example, the roof plan has 40 ft of ridge and 70 ft of soffit edges. These are lengths available for discussion, not figures for net free ventilation area. Obtain actual per-product ventilation data and ask which lengths are usable given framing, roof geometry and installation instructions.
| Line item | Value | Basis |
|---|---|---|
| Ridge length | 40 ft | Example roof plan length |
| Soffit edges | 70 ft | Example potential intake edges |
| Net free area | Product-specific | Obtain ratings and usable lengths |
PNNL attic ventilation calculation guidance · How intake and exhaust openings relate to net free ventilation area.

Bring separate interfaces into the quote
Ask how ventilation will be maintained while the roof is opened and what work is proposed at eaves, ridge, intake or roof penetrations. Record who handles insulation obstructions, duct discharge, sealing or other work beyond covering. Product compatibility and local requirements belong with the documented assembly.
Attic ventilation scope worksheet
Get a print-ready planning worksheet by email. We use your name and email to fulfill your request, not to sign you up for marketing.
Compare reroof proposals on the agreed design
If one bid adds a ridge vent and another retains existing exhaust, ask both contractors to state how their intake and exhaust strategy works. Use the flashing inventory to confirm related vent and wall connections.
- Existing design — Record attic type and existing openings.
- Intake — Record usable locations and obstruction checks.
- Exhaust — Record product, length and adjacent flashing.
- Scope gap — Assign ducts, insulation and repairs.

Sources and scope notes
We distinguish published references from worked scenarios, which are not verified contractor bids. Review product instructions and local requirements for your own project.
- PNNL attic ventilation calculation guidanceHow intake and exhaust openings relate to net free ventilation area.
- PNNL water-managed roof assemblyRoof assembly and water-management details.
- FTC home improvement hiring guidanceGuidance on written estimates, hiring and contracts.